Skip to main content

BOS

BOS LE300 Lithium 2 pack

BOS LE300 Lithium 2 pack

Request a quote with no obligation to buy.

On request

SKU: BOS Le300 2pack

Request a quote

Delivery and final amount: to be quoted.

VAT-inclusive amounts are shown for Croatia. Price, tax treatment and delivery for your destination will be confirmed in the offer.

Installation & compatibility

Product details

Description

The current original supplier description is shown. The translation is being updated.

Karakteristike proizvoda:
System voltage: 12 VDC
Norminal voltage: 12.8 VDC
Voltage range: 11 -15 VDC
Battery packs used in LE300: IFpR/26/65 [8p/4s] E/-20NA/95 LiFePO4 rechargeable battery
Nominal lithium capacity:56 Ah /716 Wh
Usable lithium capacity: 90% (50.4 Ah / 644 Wh)
Numbers of cycles at room temperature: >3000 complete cycles
Continuous charging current: Max. 25 A between 5 and 40°C, at higher and lower temperatures current is limited.
Battery efficiency: > 90%
Housing dimensions: 175 x 229 x 134 cm
Weight: 6.8 kg
Connection terminals: RAST 5/mini module 4 pin/communication, interface/external display
Recommended wire size: 1.5 – 4 mm²
Ambient temp. (operation & warehousing): -20 – 50 °C ambient temperature with, maximum battery life at 15 – 25 °C., Warehousing temperature 10 – 30 °C.
Low and high temperature protection, heating, charging & discharging: Temp. sensor prevents lithium battery charge under -5°C or above 55°C cell temp. Charging starts once cell temp. is higher than -5°C. Device has an integrated heating that is active between -20°C and 10°C cell temp. Discharge possible between -20°C and 60°C cell temp. At cell temp. below -20°C and over 60°C system is running in pure lead acid mode for higher battery lifetime.
Lithium cell balancing: Battery management inclusive balancer
Protection features: Overcurrent, overvoltage, short circuit, deep discharge, wrong polarity protection.
Operation mode/compatible external batteries: Works in combination with any 12 V lead acid battery & lead acid charge controller.
Connection possibilities: Packs can be connected in parallel with each other (see exemplary parallel combination in the table below).
Max. parallel LE300s: In standard version, a maximum of 24. LE300 can be connected only in parallel, higher quantities possible after consulting BOS partner.

Technical data

Težina
6.8 kg
Feature
System voltage: 12 VDC
Feature
Norminal voltage: 12.8 VDC
Feature
Voltage range: 11 -15 VDC
Feature
Battery packs used in LE300: IFpR/26/65 [8p/4s] E/-20NA/95 LiFePO4 rechargeable battery
Feature
Nominal lithium capacity:56 Ah /716 Wh
Feature
Usable lithium capacity: 90% (50.4 Ah / 644 Wh)
Feature
Numbers of cycles at room temperature: >3000 complete cycles
Feature
Continuous charging current: Max. 25 A between 5 and 40°C, at higher and lower temperatures current is limited.
Feature
Battery efficiency: > 90%
Feature
Housing dimensions: 175 x 229 x 134 cm
Feature
Weight: 6.8 kg
Feature
Connection terminals: RAST 5/mini module 4 pin/communication, interface/external display
Feature
Recommended wire size: 1.5 – 4 mm²
Feature
Ambient temp. (operation & warehousing): -20 – 50 °C ambient temperature with, maximum battery life at 15 – 25 °C., Warehousing temperature 10 – 30 °C.
Feature
Low and high temperature protection, heating, charging & discharging: Temp. sensor prevents lithium battery charge under -5°C or above 55°C cell temp. Charging starts once cell temp. is higher than -5°C. Device has an integrated heating that is active between -20°C and 10°C cell temp. Discharge possible between -20°C and 60°C cell temp. At cell temp. below -20°C and over 60°C system is running in pure lead acid mode for higher battery lifetime.
Feature
Lithium cell balancing: Battery management inclusive balancer
Feature
Protection features: Overcurrent, overvoltage, short circuit, deep discharge, wrong polarity protection.
Feature
Operation mode/compatible external batteries: Works in combination with any 12 V lead acid battery & lead acid charge controller.
Feature
Connection possibilities: Packs can be connected in parallel with each other (see exemplary parallel combination in the table below).
Feature
Max. parallel LE300s: In standard version, a maximum of 24. LE300 can be connected only in parallel, higher quantities possible after consulting BOS partner.
Feature
BOS LE300 Lithium 2 pack
System voltage: 12 VDC
Norminal voltage: 12.8 VDC
Voltage range: 11 -15 VDC
Battery packs used in LE300: IFpR/26/65 [8p/4s] E/-20NA/95 LiFePO4 rechargeable battery
Nominal lithium capacity:56 Ah /716 Wh
Usable lithium capacity: 90% (50.4 Ah / 644 Wh)
Numbers of cycles at room temperature: >3000 complete cycles
Continuous charging current: Max. 25 A between 5 and 40°C, at higher and lower temperatures current is limited.
Battery efficiency: > 90%
Housing dimensions: 175 x 229 x 134 cm
Weight: 6.8 kg
Connection terminals: RAST 5/mini module 4 pin/communication, interface/external display
Recommended wire size: 1.5 – 4 mm²
Ambient temp. (operation & warehousing): -20 – 50 °C ambient temperature with, maximum battery life at 15 – 25 °C., Warehousing temperature 10 – 30 °C.
Low and high temperature protection, heating, charging & discharging: Temp. sensor prevents lithium battery charge under -5°C or above 55°C cell temp. Charging starts once cell temp. is higher than -5°C. Device has an integrated heating that is active between -20°C and 10°C cell temp. Discharge possible between -20°C and 60°C cell temp. At cell temp. below -20°C and over 60°C system is running in pure lead acid mode for higher battery lifetime.
Lithium cell balancing: Battery management inclusive balancer
Protection features: Overcurrent, overvoltage, short circuit, deep discharge, wrong polarity protection.
Operation mode/compatible external batteries: Works in combination with any 12 V lead acid battery & lead acid charge controller.
Connection possibilities: Packs can be connected in parallel with each other (see exemplary parallel combination in the table below).
Max. parallel LE300s: In standard version, a maximum of 24. LE300 can be connected only in parallel, higher quantities possible after consulting BOS partner.
BOS LE300 Lithium 2 pack

Installation & compatibility

What is included

Exact supplied items are confirmed for the chosen model in your quotation. Refer to the description and model documents for published package details.

Additional components to check

Charger and charging sources, cabling, terminals, electrical protection and monitoring connections as applicable.

These are planning checks for the complete system. Some components may already be included or installed on your vessel.

Compatibility checks

Charging profiles, system voltage, current ratings, dimensions and communications. Series/parallel connections must be permitted for the exact model.